User's Guide
Enter Setup
** Exit Setup
28
Trigger Commands
When Enable Trigger Commands is selected, you can activate and deactivate the scanner in the Level mode with serial
trigger commands. Sending the Start Scanning command (default: <SOH> T <EOT>, user-programmable) to the scanner
in the Level mode activates a decode session. The decode session continues until a barcode is decoded or the decode
session timeout or the scanner receives the Stop Scanning command (default: <SOH> P <EOT>, user- programmable).
** Disable Trigger Commands
Enable Trigger Commands
Modify Start Scanning Command
The Start Scanning Command canstimulate the trigger unreleased andconsist of 1-10 characters (HEX values from
0x01 to 0xFF). In this command, the character “?” (HEX: 0x3F) cannot be the first character. The default Start Scanning
command is <SOH> T <EOT>.
Modify Start Scanning Command
Set the Start Scanning command to “*T”:
1.
Scan the Enter Setup barcode.
2.
Scan the Modify Start Scanning Commandbarcode.
3.
Scan the numeric barcodes “2”, “A”, “5” and “4” from the “Digit Barcodes” section inAppendix.
4.
Scan the Save barcode from the “Save/Cancel Barcodes” section inAppendix.
5.
Scan the Exit Setup barcode.