User's Manual Part 1

2-12 Saja Operation Manual
10/12/00
Installation Chapter2.fm
2.4 Connecting the Power Cord
Connect the printer to an AC outlet as described below.
Warning:
Three power specifications are listed below. The spec-
ifications that apply to your machine depend on your
machine configuration. Connect the power plug only
to a properly rated power outlet. Otherwise, it can
cause a fire or shock hazard. If in doubt, contact the
Xerox Customer Support Centre.
- Rated voltage: 100V
Rated frequency: 50/60Hz
- Rated voltage: 120V
Rated frequency: 50/60Hz
- Rated voltage: 220-240V
Rated frequency: 50/60Hz
To prevent a fire or shock hazard, follow the instruc-
tion below based on your machine configuration. If in
doubt, contact the Xerox Customer Support Centre.
- If your machine is a 220-240V model, there is no
need to attach a separate earth line since the earth
connection is incorporated in the power line. Plug it
into a properly rated outlet.
- If your machine is a 100 or 110V model, use the
green earth wire bundled with the power cord,
located at the rear of the machine.
The earth wire must be connected to one of the fol-
lowing conductors.
Earth terminal of the specified power outlet
A piece of copper buried in the earth 650mm or
deeper
Earth terminal with Class 3
*
earthing.
* Class 3 is the regulation for Japan only.
1. Insert the power cord into the AC connector on the rear of the printer.
Warning:
Never touch the power cord or plug with wet hands, to
prevent the risk of electric shock.
Caution:
When disconnecting, always grasp the plug and do not pull
on the cable. Damage to the cord can lead to fire and electric
shock.