Owner's Manual
NOTE: Do not use natural gas orifices with an LP gas tank or LP gas orifices with natural gas. Do gas leakage testing
after per conversion. Please note the Gas Hook-Up, Danger, and Warnings pages in the manual for more information.
E. Connect the NG hose assembly to fixed NG
piping system. (FIG. 04) Turn on gas supply
and do the leak testing as the procedures
shown on page 26 of main manual. Read all
lighting instructions on main manual prior to
lighting.
F. Remove the control knob, knob bezel and
control valve. FIG 05.
G. Turn the valve adjusting screw counter
clockwise 100%. FIG 06.
H. Re-install the control knob bezel, valve and
knob using the same Phillips head screws.
FIG 07.
I. After the conversion is done, apply the rating
plate on the unit.
1. The outdoor cooking gas appliance and its
individual shutoff valve must be
disconnected from the gas supply system
during any pressure testing of that system
at test pressures in excess of
0.5psi(3.5kpa)
2. The outdoor cooking gas appliance must
be isolated from the gas supply piping
system by closing its individual manual
shutoff valve during any pressure testing
of the gas supply piping system at test
pressures equal to or less than
0.5psi(3.5kpa).
FIG 04.
FIG 05.
FIG 06.
FIG 07.