Instructions / Assembly

28$
knobs and battery to disable accidental ignition. Open the tank
storage door containing the LP or natural gas hook up, this is
where all tests will be performed.
To Test:
Make sure all control valves are in theOFF position. Turn the
gas supply “ON”. Check all connections from the supply line, or
LP cylinder up to and including the manifold pipe assembly.
Apply the soap solution around the connection, valve, tubing
and end of the manifold. Soap bubbles will appear where a
leak is present. If a leak is present, immediately turn off gas
supply, tighten any leaking connections, turn gas on, and
recheck. Check all the gas connections at the base of the
control valves where they screw into the manifold pipe. If you
cannot stop a gas leak, turn off the gas supply and call your
local gas utility or Fuego customer service at 888-88FUEGO
(38346). Only those parts recommended by the manufacturer
should be used on the grill. Substitution can void the warranty.
WARNING:
Do not use the grill until all connections have been checked
and do not leak. Check all gas supply fittings for abrasions,
cracks and leaks before each use. It is recommended to keep a
spray bottle filled with soapy water near the shutoff valve of
the gas supply valve. Spray all the fittings. Bubbles indicate
leaks. (FIG. 2)