Full Product Manual

Natural Gas Models (NG)
Check with your gas utility or with local building codes for instructions to install gas supply line, or call a
licensed and knowledgeable installer.
It is recommended that an “ON-OFF” shutoff valve be installed at the gas supply source.
Pipe sealing compound or pipe thread tape of the type resistant to the action of natural gas must be
used on all male pipe thread. Apply compound or tape to at least the first three threads when making
the connection.
Disconnect your gas grill from fuel source when the gas supply is being tested at high pressures. This
appliance and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at pressures in excess of 1/2 psig (3.5 KPa)/37 mbar.
Turn off your gas grill when the gas supply is being tested at low pressures. This appliance must be
isolated from the gas supply piping system by closing its individual valve.
WARNING:Gas valves are preset at the factory to operate on LP or natural gas. If you wish to convert
to a different gas type, be sure to contact your grill dealer, licensed plumber or authorized service
center for further details. Conversion kits are not sold to the general public and require a professional
to perform service. Failure to properly convert a unit can cause serious injury to yourself and/or others,
irreparable damage to your grill and void of warranty.
Model Number
Maximum BTU/HR
Propane Pressure
F27S-Pizza-NG
37,000
7” Water Column