Ventilation Requirements (All Models)
The island must be constructed of NON-COMBUSTIBLE Materials Only.
Keep in mind when choosing a location for your grill that it should NOT be located under
any overhead combustible construction.
Upper and lower level vents must be provided for combustion air on both sides of built-in
cabinet. Vents on BBQ insert must remain unobstructed to allow for combustion air and
ventilation.
Upper vents must be located within 5 inches/12.7 cm from the top of the island enclosure
to the bottom of the vent.
Lower vents must be located within 1 inch/2.54 cm from the bottom of the island
enclosure to the bottom of the first vent openings and no more than 5 inches/12.7 cm
from the bottom of the island enclosure to the top of the vent.