User's Guide
PAGE 2 - Main operation status display
Standby surveillance mode
+24。C
The detected temperature, when there are more than
one temperature sensors, they will display the
highest temperature value among them and use the
highest temperature to judge if to launch the excess
temperature protection action
LCsacn LC infers to the resonant TANK constituted by the
coil and the capacitance, the mode is to scan such
resonant frequency and use the gained value to judge
if it is necessary to enter into the power supply
action
74.3KHz The current detected resonant frequency is 74.3KHz
24.02V The current input voltage is 24.02 V
0.01A The current input electricity is 0.01A
0.2W The current input power is 0.2W
72.0/Hi Set the upper resonant frequency limit of the RX
launching electricity transmission
66.4/Lo Set the lower resonant frequency of the RX launching
electricity transmission
The measurement of resonant frequency need to be
between the upper and the lower limit, will it be
launched to transmit the electricity
Search. Searching if there is RX approaching
t Already launched the control of thrust system
*press C in the screen will switch to drive mode
t is the thrust control mode (thrust control on)
F is the full-thrust mode (thrust control off)