User's Guide

PAGE 3 - System limit value display
Limit value display list
Tx Limit Tx indicates the power supply port, the content of
this page is the limit value of power supply’s input
power
23.91 V The current measured input voltage is 23.91V
9.01 A The current measured input current is 9.01A
215.4 W The input power calculated from the measured voltage
and the current is 215.4W
V ≥ 23.0 Over low voltage protection limit value, if lower
than the value it will launch the UVP
V ≤ 25.0 Over high voltage protection limit value, if higher
than the value it will launch OVP
A ≤ 13.0 Over high current protection limit value, if higher
than the value it will launch the OCP
W ≤ 300 Over high power protection limit value, if higher
than the value it will launch the OPP
UVP launching
22.37 V The current measured input voltage is 22.37 volt
UVP>7 Lower than the limit value, 10 seconds after
starting counting the time it will launch UVP
protection, the current timing is at the 7 second
This is under the condition of the measured voltage
is still close to the limit value, it will conduct
counting second timing
If the gap is too large, it will launch
automatically