User's Guide
Wireless power transmitting
Tx No data signal from RX has been received
19/ 200 Under the condition of RX breaking signals, as long
as the RX measuring coil position does not move, it
will not immediately cut off electric the power
transmission and it will enter into timing process,
after time’s up, if there is still no signal
recovered then it will cut off the electric power.
19/200 means timing to 200 will cut off the electric
power, and the current time counting is 19. At this
moment the timer will increases 20 values in every
second, and 200 is the time length of 10 seconds.
The end of wireless power transmission
RxEND27.6 V After ending the electric power transmission, the
last receiving RX port voltage data is 27.6V
Wireless power transmitting
+41。C
Detected temperature
*the sample limits the temperature to be 40 degree
OT!2 Caution of over high temperature, time for the 2
second, when the time of the over high temperature
reaches 10 seconds it will be locked for protection