Upwards arrow shows the measurement result of the
value compared to the last time is performing the
uptrend
↘
Downwards arrow shows the measurement result of the
value compared to the last time is performing the
downtrend
Power transmission launching detection mode (thrust control off)
t-off Thrust control off
Standby detection mode RX coil is approaching
COIL ERROR RX device is approaching, after launching the power
transmission detection the RX device has no
response, if the result happens again and again that
the RX is approaching, it might be the breakdown of
the RX circuit
wireless power transmitting
FOD→▌ After RX is approaching and it starts to supply the
power, turn on the detection status of the metal
foreign body detection function
There are four type of thickness, the thicker shows
the higher possibility of metal foreign body
If the sign is “?”, it shows invalid of the current
detection