User`s manual
User’s manual · TSF 310 CI
- 7 - TSF 310 CI version_en_2.0 FTE maximal
- NM low Limit (dB): An event of error will be recorded when the value
of Noise Margin is lower than the set value.
- NM hight limit (dB): Once the event of error is recorded (Noise
Margin < Limit Lower NM), this will be Noise Margin value that will
have to be exceed so the module stops being in error.
- Clear log all devices. It allows deleting the events report of all the
interconnected modules.
- Factory default: This option restores the values by default of the
transmodulator.
- System information: It allows you to visualize the basic information of the
module: model, no of series, firmware version, etc.
- Settings: This option allows saving and loading the configuration of the
module, carrying out firmware update or making an adjustment of the time and
date of the module.
- Clock:
- Set Date and time: Setting of the date and time of
transmodulator. It is appropriate to maintain these parameters
set in order to have the registration of errors linked to the
current time and date.
- Set date/time all devices: Loading the current date and time
of the module in the rest of interconnected modules.
- Alias:
- Write alias: It allows you to assign a name/alias to the
module you are programming. Option only available when the
Alias Auto option is configures as “none” (manual mode).
- Auto Alias: It allows configuring the name/alias of the
modules automatically. Options: Channel, Frequency, Service,
None.
- Upgrade:
- Send Firmware from USB: It allows carrying out the firmware
update from the USB device.
- Send firmware to all: It allows carrying out the update of all
the modules that are interconnected at the same time.
- Configure all devices:
- Input values to all devices: It allows copying the current input
configuration in all the interconnected modules.
- Modulator values to all devices: It allows copying the
configuration of the current modulator in all the interconnected
modules.
- Output values to all devices: It allows copying the current
output configuration in all the interconnected modules.
- Factory default to all devices: It allows making values by
default to all the interconnected modules.
-
(1)
Activate the following output:
- It allows activating or deactivating the output of the second
Unit.
Note: This option is available only in devices with a serial number higher than a 075511441882.