User`s manual

User’s manual · TSF 310 CI
- 15 - TSF 310 CI version_en_2.0 FTE maximal
-
(1)
LCN: The LNC function allows assigning automatically a predetermined
position to each one of the services of the multiplex. This function will allow the
users who have a receiver with LNC support to make the ordination of channels
automatically.
Select a channel through Left/Right buttons and introduce the position. Press the
“OK” button and the cursor will be placed over the number. With the keys of the
cursor, we can move through all the digits and change the values. Press “OK” in order to save the changes.
Note: If in the existing installation there are already services that have LNC system, you will have to configure
the position of the module services in order to avoid conflicts with other net services.
-
(1)
Decrypt services: From this option you can add or remove manually the services that are being decoded by the card:
- Delete services
- Add services
-
(1)
CAM Reset : It allows making a reset in the selected CAM.
- Date / Hour: Setting of the date and time of transmodulator. It is appropriate to maintain these parameters set in order to
have the registration of errors linked to the current time and date.
- SW version info: It allows you to visualize the basic information of the module: model, firmware version, etc.
-
(2)
MUX number: It configures the number of output multiplex. Options: 1 or 2.
- Global Update: It allows carrying out the update of all the modules that are interconnected at the same time.
Note:
(1)
If the serial number of the device is higher than 075511441882, you have to select in which one of the two modules you want to make the
configuration in each case.
(2)
This option is available only in devices with a serial number higher than a 075511441882.
TSF 310 CI