Datasheet
User’s guide · RCM 310
- 4 - RCM 310 version_en_1.0 FTE maximal
Note: If you insert the SIM card while the device is on, the modem will not detect it. You will have to turn the
device off and on so it can be detected by the modem. If you do not insert any SIM card in the RCM310 the
features concerning neither the SMS nor the GPRS browsing will not be available.
The provided GSM antenna should be plugged in the corresponding connector in the front panel. Keep in mind that the
system will not detect any GSM/GPRS net unless the antenna is connected.
1.8. Boot sequence
The RCM 310 switches on the Led 1 during the boot sequence. This Led remains switched on during the boot sequence
(it lasts one minute and a half approximately). It is not possible to establish connections with the web service of RCM 310
until the boot sequence is finished. Once the sequence is finished, the led L1 switches off (or turns into its corresponding
status according to the configuration of the RCM 310), which means that the RCM is ready to operate normally.
1.9. Connecting to the RCM310 through Ethernet
In order to connect to the RCM 310 through Ethernet, it must be connected to a net.
The IP address by default of the RCM 310 is:
192.168.1.227
Note: Make sure that there are no other devices with this same IP address in the net. If any doubts connect
directly (with a straight or crossed RJ45 cable) to the RCM 310 in order to avoid problems in the net. Once
connected to the RCM 310 you will be able to change the configuration in order to adapt it to the net where it
will be connected.
1.10. Connecting to the web server of RCM310
Log in the browser and write down the IP address of the RCM 310 in the address bar. If everything has run properly, you
will see the connection window of the web server.