Datasheet
User’s guide · RCM 310
- 34 - RCM 310 version_en_1.0 FTE maximal
Chapter 9. Restoring the system up to the inicial settings
It is possible to restore the RCM 310 up to its original default settings through a special procedure. This procedure is only
recommended in case the system does not answer, or might the parameters to gain access to the device are lost.
Note: The rebooting process of the RCM 310 to its default values is irreversible and it destroys all the data and
configurations that were stored in the device. It is recommended to have back-ups of the RCM 310
configurations.
The procedure for restoring the RCM 310 up to its default values is the following:
• Turn the device off.
• Press the “boot” button in the front panel with a sharpening object while connecting the supply to the device.
• When the red led starts flicking you can let the “boot” button go.
• The green led will turn on while the red one will remain fixedly on.
• The red led will turn off after a few seconds and the Green led will remain on.
• Once the Green led is on and the red one off, disconnect the supply of the device and connect it again. The
device will be restored up to its default settings and you will be able to connect to it with these settings.