User’s guide · RCM 310
- 29 - RCM 310 version_en_1.0 FTE maximal
Monitoring an external signal
This option allows adding a new external signal. The parameters that have to be entered for each one of the external
signal that you create are the following:
Alias: The external signal will be identified with the name you give to it.
Minimum RF: This is the minimum value that the signal can have in normal conditions. If the signal level is
becomes lower than this minimum, you can set an alarm configuration that generates an output action.
Maximum RF: This is the maximum value that the signal can have in normal conditions. If the signal level is
becomes higher up than this maximum, you can set an alarm configuration that generates an output action.
Frequency: This is the central frequency of the channel, it does not matter if it is an analogue signal or a digital
one.
Digital / Analogue: You have to specify if the monitored signal will be digital or analogue.
Once all the data has been filled press “create”. This will refresh the page and you will be able to create a new signal in the
signal list below.
Withdrawing an external RF signal
This option allows deleting an external RF signal. In order to do so, just select the signal from the list and press “delete”.
Modifying the Alias and RF limits
This option allows modifying the alias and RF limits for the external signals as well as for the devices that are connected to
the DVBUS.
The RF signals appear in the list without “UID” since they do not correspond to any device.
In the RF limits of the connected devices, neither the frequency nor the type of signal can be changed since these
parameters are configured in the device.