Activate according to the devices status:
Warning. The device moves to the warning status.
Error. The device moves to the error status.
No answer. The device does not answer to the RCM310.
RF range OK. The level measured in the output of the device is within the specified range.
Signal out of range. The level measured in the output of the device is out the specified range.
Activate according to the external RF Status:
RF range OK. The level measured in the output of the device is within the specified range.
Signal out of range. The level measured in the output of the device is out the specified range.
Activation according to the status of other alarms
The system is able to use another alarm as a source of alarm. This allows creating complexes alarms settings,
where previous alarms must take place in order to generate other ones.
Activation according to the digital inputs status
A digital input that is opened or closed is a source for an alarm.
Activation when receiving a text message
The SMS reception with a predefined message can be used as a source for generating an alarm.
Note: When using the SMS reception as an alarm source it is important to use the “Immediate deactivation of
the alarm once activated” option, since in order to deactivate the alarm the requirements for starting it must stop
and there is no contrary when receiving the SMS. Therefore, if the immediate deactivation is not chosen, the
alarm generated by the SMS reception will remain active every time.