Single Layer Application of FT SILVER
For slopes greater that 4:12 FT SILVER should be installed horizontally starting
from the bottom of the roof with 4 inch overlaps working up the roof.
48“ (122 cm)
6” (150 mm)
Vertical Overlap
4” (100 mm)
Horizontal Overlap
Roof Deck
Fasten underlayment
as specified in the
installation instructions
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
Fasten underlayment
as specified in the
installation instructions
Eave Drip Edge Under Underlayment
Rake Drip Edge
Over
Underlayment
48“ (122 cm)
25“ (64 cm)
25“ (64 cm)
Roof Deck
Double Layer Application of FT SILVER
For slopes 2:12 to 4:12 FT SILVER should be installed horizontally starting from the
bottom of the roof with 25 inch overlaps working up the roof.