Datasheet

TECHNICAL SPECIFICATIONS
PHASE
Single phase with ground
CAPACITY
1000 VA / 900W 2000 VA / 1800W 3000 VA / 2700 W 6000 VA / 5400 W 10000 VA / 9000 W
INPUT
Voltage Range
Nominal Voltage
120-300 VAC (Based on load at 50%)
180-280 VAC (Based on load at 100%)
200/208/220/230/240 VAC
110-300 VAC (Based on load at 50%)
176-300 VAC (Based on load at 100%)
208/220/230/240 VAC
Frequency Range 40Hz ~ 70 Hz 46~54 Hz or 56~64 Hz
Power Factor
0.99 @ Nominal Voltage (100% Last)
OUTPUT
Nominal Voltage 200/208/220/230/240 VAC 200/208/220/230/240 VAC
AC Voltage Regulaon ± 1% ± 1%
Frequency Range(Synchronized Range) 47~ 53 Hz or 57 ~ 63 Hz 46~54 Hz or 56~64 Hz
Frequency Range(Ba. Mode)
50 Hz or 60 Hz ± 0.5% 50 Hz or 60Hz ± 0.1 Hz
Current Crest Rao 3:1 3:1
Harmonic Distoron
3 % THD (Linear Load),
6 % THD (Non-linear Load)
3 % THD (Linear Load),
5 % THD (Non-linear Load)
Transfer
Time
AC mode to Baery mode Zero Zero
Zero4 ms (Typical)
Inverter to Bypass
Waveform (Ba. Mode) Pure Sinewave
EFFICIENCY
Line Mode 89%
Baery Mode 85%
88%
83%
90%
88%
92%
90%
93%
91%
BATTERY
Baery Type 12V / 9 Ah 12 V / 9 AH
Numbers
Typical Recharge Time
2 6
12 V / 9 AH
16
12 V / 9 AH
16
Charging Current (max.) 1.0 A
12V / 9 Ah
4
4 hours recover to 90% capacity 9 hours recover to 90% capacity
1.0 A 1.0 A 1A/2A (Adjustable)
27.4 VDC ± 1% 54.7 VDC ± 1% 82.1 VDC ± 1%
218.4 VDC ± 1% 218.4 VDC ± 1%
Charging Voltage
INDICATORS
LCD Display Last level, Baery level, AC mode, Baery mode, Bypass mode, and Fault indicators
ALARM
Baery Mode Sounding every 4 seconds
Low Baery Sounding every second
Overload
Sounding twice every second
Fault Connously sounding
PHYSICAL
Dimension,
D x W x H(mm)
282 x 145 x 220 397 x 145 x 237 421 x 190 x 336
Net Weight (kgs) 9.8
17.0
17.6
UPS Unit:
369 x 190 x 688
Baery Pack:
369 x 190 x 318
UPS Unit: 61
Baery Pack:49
UPS Unit:
442 x 190 x 688
Baery Pack:
442 x 190 x 318
UPS Unit: 66
Baery Pack:49.5
ENVIRONMENT
Operaon Humidity 20-90% RH @ 0-40°C (non-condensing)
Noise Level Less than 50 dBA @ 1 Meter
0-95% RH @ 0-50°C
(non-condensing)
0-95% RH @ 0-40°C
(non-condensing)
Less than 50 dBA @ 1 Meter Less than 58 dBA @ 1 Meter
MANAGEMENT
Smart RS-232 / USB
Oponal SNMP
Power management from SNMP manager and web browser
Supports Windows 2000/2003/XP/Vista/2008/7, Linux and MAC
*1-3KVA: Derate to 80% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to 100/200/208VAC.
6-10KVA: Derate to 60% of capacity in Frequency converter mode and to 90% when the output voltage is adjusted to 208VAC.
Product specificaons are subject to change without further noce.
Champ Series
AC INPUT & OUTPUT CONNECTORS
1 x IEC 320 C14
3 x CEE 7/4 (Schuko)
1 x IEC 320 C14
3 x CEE 7/4 (Schuko)
1 x IEC 320 C20
4 x CEE 7/4 (Schuko)
AC Input Connector
AC Output Connector
STANDARDS
17
Safety / EMC IEC 62040-1 (safety) / IEC-62040-2 (EMC) / CE
Backup Time Table for Champ Series
Backup Time with Load (Min)
Battery Bank 25% 50% 75% 100 %
CH 1101TS
CH 1102TS
CH 1103TS
CH 1106TS
CH 1110TS
Internal baery only (24V:12V-9Ah x 2)
Internal baery only (48V:12V-9Ah x 4)
Internal baery only (72V:12V-9Ah x 6)
Internal baery (192V:12V-9Ah x 16)
+1 external baery (192V: 12V-9AH x 32)
Internal baery (192V:12V-9Ah x 16)
+1 external baery (192V: 12V-9AH x 32)
20
25
26
42
78
22.3
53
9.0
10
10
17.8
32
8.7
22
5.0
6.0
6.0
10
18.6
4.8
13
3.0
3.0
3.0
6.8
12.6
2.3
8.7
Terminal block
MODEL
CH-1101T CH-1103T CH-1106T CH-1110TCH-1102T
www.fsp-ps.de