User manual

5. Trouble Shooting
Use the table below to solve minor problems.
Problem
Possible Cause
Solutions
No LED display on the
front panel.
Low battery.
Charge the UPS at least 8 hours.
Battery fault.
Replace the battery with the same
type of battery.
The UPS is not turned on.
Press the power switch again to turn
on the UPS.
Alarm continuously
sounds when the
mains is normal.
The UPS is overload.
Remove some loads first. Before
reconnecting equipment, please
verify that the load matches the UPS
capability specified in the specs.
UPS fault
Return the unit to the service center.
Alarm sounds every 2
seconds when the
mains is normal.
Battery defect.
Replace the battery with the same
type of battery.
Charging board is damaged.
Return the unit to the service center.
When power fails,
back-up time is
shorten.
The UPS is overload.
Remove some critical load.
Battery voltage is too low.
Charge the UPS at least 8 hours.
Battery defect. It might be
due to high temperature
operation environment, or
improper operation to battery.
Replace the battery with the same
type of battery.
The mains is normal
but LED is flashing.
Power cord is loose.
Reconnect the power cord properly.
6 Specifications
Model
Nano 400
Nano 600
Nano 800
CAPACITY
400 VA / 240 W
600 VA / 360 W
800 VA / 480 W
INPUT
Voltage
Voltage Range
Frequency
OUTPUT
Voltage Regulation
Transfer Time
Waveform
BATTERY
Type & Number
12 V / 4.5 AH x 1
12 V / 7 AH x 1
12 V / 9 AH x 1
Charging Time
PHYSICAL
Dimension (DxWxH)
Net Weight (kgs)
2.2
2.7
3.1
Environment
Humidity
Temperature
1. Lieferumfang
Im Lieferumfang sollten Sie folgendes finden:
- UPS Einheit
- Schnell Installationsanleitung
- Stromkabel ( nur für IEC-input Modell)
2. Produktübersicht
Vorderansicht:
ckansicht:
Standby UPS Quick Guide V. 1.1
Netzschalter
UPS Statusanzeige
Status der Schuld/Batterie
AC input
Ausgabe Anschluss
4
5
DE