Datasheet

9
Environmental conditions.
5.1. TEMPERATURE RANGE
Operating 350W 0 to +50 deg. C
Storage -20 to +80 deg. C
5.2. HUMIDITY
Operating 5 –85% RH, Non-condensing
Storage 5 –95% RH, Non-condensing
5.3. VIBRATION
The subject power supply will withstand the following imposed conditions without experiencing
non-recoverable failure or deviation from specified output characteristics.
Vibration Operating – Sine wave excited, 0.25 G maximum acceleration, 10-250 Hz swept at one
octave / min. Fifteen minute dwell at all resonant points, where resonance is defined as those
exciting frequencies at which the device under test experiences excursions two times large than
non-resonant excursions.
Plane of vibration to be along three mutually perpendicular axes.
5.4. SHOCK
The subject power supply will withstand the following imposed conditions without experiencing
non-recoverable failure or deviation from specified output characteristics.
Storage 40G, 11 mSec. half-sine wave pulse in both directions on three mutually
perpendicular axes.
Operating 10G, 11mSec. half-sine wave pulse in both directions on three mutually
Perpendicular axes.
6. SAFETY
6.1. LEAKAGE CURRENT
In addition to the UL,CSA safety requirements,the leakage current from AC to safety ground will
not exceed 3.5mA-rms at 264Vac,63Hz
7. ELECTORMAGNETIC COMPATIBILITY
7.1. RADIATED EMI
文件資料管制 文件資料管制 文件資料管制