6.1. TEMPERATURE RANGE
Operating +10 to +50 deg. C
Storage -20 to +80 deg. C
6.2. HUMIDITY
Operating 5 –95% RH, Non-condensing
Storage 5 –95% RH, Non-condensing
6.3. VIBRATION
The subject power supply will withstand the following imposed conditions without experiencing
non-recoverable failure or deviation from specified output characteristics.
Vibration Operating – Sine wave excited, 0.25 G maximum acceleration, 10-250 Hz swept at one
octave / min. Fifteen minute dwell at all resonant points, where resonance is defined as those
exciting frequencies at which the device under test experiences excursions two times large than
non-resonant excursions.
Plane of vibration to be along three mutually perpendicular axes.
6.4. GROUND LEAKAGE CURRENT
The power supply ground leakage current shall be less than 3.5 mA.
6.5. RELIABILITY
The power supply reliability,when calculated by MIL-HDBK-217;latest revision, are exceed
100,000 hours with all output at maximum load and an ambient temperature of 25℃.
6.6. DIELECTRIC STRENGTH
Primary to Frame Ground : 1800 Vac for 1 sec.
Primary to Secondary : 1800Vac for 1 sec