4.4. OUTPUT RISE TIME
(10% TO 95% OF FINAL OUTPUT VALUE, @ FULL LOAD)
115V-rms or 230V-rms + 3.3Vdc : 20ms Maximum
+ 5Vdc : 20ms Maximum
+ 12Vdc : 20ms Maximum
+ 5Vsb : 20ms Maximum
- 12Vdc : 20ms Maximum
- 5Vdc : 20ms Maximum
4.5. OVER VOLTAGE PROTECTION
Voltage Source Protection Point
+3.3V 3.76V-4.8V
+5V 5.6V-7.0V
+12V 13.0V-16.5V
4.6. OVER CURRENT PROTECTION
Output Voltage Max. over current limit
+3.3V 60A
+5V 48A
+12V1 25A
+12V2 30A
4.7. SHORT CIRCUIT PROTECTION
Output short circuit is defined to be a short circuit load of less than 0.1 ohm.
In the event of an output short circuit condition on +3.3V, +5V, +12V or –12V output, the power
supply will shutdown and latch off without damage to the power supply. The power supply shall
return to normal operation after the short circuit has been removed and the power switch has been
turned off for no more than 2 seconds.