Datasheet

6
4.2. LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits DC include DC Output
ripple & noise.
LOAD +3.3V +5V +12V1 +12V2 -12V -5V +5VSB
Condition_1 X X X X X X 2.5A
Condition _2 0.2A 0.2A 0.1A 0.5A 0A 0A 0A
Condition _3 0.3A 0.2A 1A 0.5A 0.5A 0A 0.05A
Condition _4 0.5A 3A 15A 12.5A 0A 0A 0.5A
Condition _5 0.1A 15A 2A 2A 0A 0.3A 0.5A
Condition _6 1A 20A 10A 9A 0.5A 0A 2.5A
Condition _7 10A 10A 6A 15A 0.25A 0.2A 2A
Condition _8 18A 2A 2A 2A 0A 0A 1A
Condition _9 21A 7.1A 9.8A 9A 0.5A 0.1A 2.5A
Condition _10 8.5A 8A 10A 8A 0.5A 0.1A 2.5A
4.3. HOLD-UP TIME (@Condition _10)
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
The output voltage will remain within specification, in the event that the input power is removed or
interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any
point in the AC voltage cycle. The power good signal shall remain high during this test.