Datasheet

Page8
4.0 Physical Environment
4.1 Temperature
4.1.1 Operating Ambient: +0 to 40
4.1.2 Non-Operating Ambient(Storage): 40 to +70
4.2 Humidity
4.2.1 Operating: To 85% relative humidity (non-condensing)
4.2.2 Non-Operating: To 95% relative humidity (non-condensing)
Note:
95%RH is achieved with a dry bulb temperature of 55 and a wet bulb
temperature of 54.
4.3 Altitude
4.3.1 Operating: To 10,000ft
4.3.2 Non-Operating: To 50,000ft
5.0 Regulatory Compliance
5.1 Safety Requirements
-IEC 950
-CB REPORT
-TUV EN 60950
-ULOR CUL
-BSMI
-CCC
5.2 Dielectric Strength
Primary to Frame Ground: 1800 Vac for 1 sec.
Primary to Secondary: 1800 Vac for 1 sec.
5.3 Insulation Resistance
Primary to Secondary: 20 Meg. ohms minimum.
Primary to FRAME GROUND: 20 Meg. ohms minimum.
5.4 Ground Leakage Current
The power supply ground leakage current shall be less than 3.5mA.
5.5 Emission Requirements
The power supply shall comply with CISPR 22, Class B, for both conducted and
radiated emissions with a 4dB margin..
文件資料管制 文件資料管制 文件資料管制
8/9禁止翻印外洩 ESD10049826-R6.pdf 發行時間:2011/4/18 3:57 下午