Datasheet
Page4
LOAD REGULATION CHARACTERISTICS
OUTPUT LOAD
12V
NO.
LOAD
CONDITION
+3.3V +5V +12V1 +12V2 -12V +5Vsb
1
COND.1 X X X X X 3.5A
2
COND.2 X X X X X 3A
3
COND.3 0.1A 0.2A 0.1A OA 0A 0A
4
COND.4 21A 1A 2A 2A 0.1A 0.1A
5
COND.5 0.1A 15A 2A 2A 0.1A 0.1A
6
COND.6 2A 2A 14A 14A 0A 0.1A
7
COND.7 3.6A 3.6A 2.6A 2.4A 0.1A 0.2A
8
COND.8 9A 9A 6.5A 6A 0.15A 0.5A
9
COND.9 10A 12A 12A 12A 0.3A 0.05A
10
COND.10 10.89A 7.78A 10.9A 10.9A 0.22A 2.18A
11
COND.11 10A 10A 12A 12A 0.3A 2A
Cond. 11 Over load test,115Vac/60Hz and less then 0.5S,Regulation is ±6%.
Cond. 1 at 115Vac/60Hz and less then 100 mS
3.2 REMOTE ON/OFF CONTROL
The power supply shall accept a logic open collector level which will disable/
enable all the output voltage (exclude + 5V standby).
As logic level is low, outputs voltage were enabled.
As logic level is high, outputs voltage were disabled.
Note: 1. Logic high level: 2.0-5.25V while sourcing 0.2mA maximum.
2. Logic low level: 0-0.5V while sinking 1.6mA maximum.
3. Rise Time: 15ms maximum (10%-90%).
3.3 OUTPUT VOLTAGE HOLD-UP TIME
17.0 mS minimum : at 115V / 60 Hz. (100%LOAD,COND 10)
3.4 OPERATION AT NO LOAD
The power supply shall be capable of being operated with no load on any or
all outputs without damage. For no load on +3.3V & +5V, the output shall not
exceed +4.3V & +6.5Vdc and the power supply may shutdown and require
by remote-control or remove AC power restart.
3.5 PROTECTION
3.5.1 Over-voltage protection
In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the
power supply shall shutdown and require remote control or remove the AC
mains input to reset the system.
+5V : 6.7V (maximum)
+3.3V : 4.3V (maximum)
+12V : 15.6V (maximum)
文件資料管制 文件資料管制 文件資料管制
4/9禁止翻印外洩 ESD10049826-R6.pdf 發行時間:2011/4/18 3:57 下午