Datasheet
7
+3.3V 3.76V - 4.8V
+5V 5.6V - 7.0V
+12V 13.0V - 16.5V
4.6. OVER CURRENT PROTECTION
Output voltage Max. over current limit
+3.3V 60A
+5V 48A
+12V1 27A
+12V2 27A
4.7. SHORT CIRCUIT PROTECTION
Output short circuit is defined to be a short circuit load of less than 0.1 ohm.
In the event of an output short circuit condition on +3.3V, +5V, +12V or–12V output, the power
supply will shut down and latch off without damage to the power supply. The power supply shall
return to normal operation after the short circuit has been removed and the power switch has been
turned off for no more than 2 seconds.
4.8. POWER SIGNAL
Figure:
T1: Power-on time shall be less than 500 ms (T1 < 500 ms).
T2:
Rise time : 0.1 ms to 20 ms (0.1 ms ≤T2 ≤20 ms).
T3: Power-ok delay time: 100 ms < T3 < 500 ms
POWER GOOD @115/230V, FULL LOAD 100 –500mSec.
POWER FAIL @115/230V, FULL LOAD 1 mSec. minimum
文件資料管制 文件資料管制 文件資料管制 All rights reserved
7/9禁止翻印外洩 All rights reserved ESD16025495-R1.pdf 建立時間:2016/5/18 3:38 下午