Datasheet

9
The power supply reliability when calculated by MIL-HDBK-217; latest revision, are exceed
100,000 hours with all output at 80% full load and an ambient temperature of 25℃.
6.6. DIELECTRIC STRENGTH
Primary to Frame Ground : 1800 Vac for 1 sec.
Primary to Secondary : 1800Vac for 1 sec
6.7. INSULATION RESISTANCE
Primary to Frame Ground : 20 Meg.ohms Minimum
Primary to Secondary : 20 Meg.ohms Minimum
7. LABELLING
Label marking will be permanent, legible and complied with all agency requirements.
7.1. MODEL NUMBER LABEL
Labels will be affixed to the sides of the power supply showing the following:
- Manufacturers name and logo.
- Model no., serial no., revision level, location of manufacturer.
- The total power output and the maximum load for each output.
- AC input rating.
8. MECHANICAL SPECIFICATIONS
The mechanical drawing of the subject power supply, which indicate the form factor, location of the
mounting holes, location, the length of the connectors, and other physical specifications of the
subject power supply. Please refer to the attachment drawing.
文件資料管制 文件資料管制 文件資料管制 All rights reserved
9/9禁止翻印外洩 All rights reserved ESD16025495-R1.pdf 建立時間:2016/5/18 3:38 下午