Datasheet

6
250W Load condition
No. +3.3V +5V +12V1 +12V2 -12V +5Vsb
FL1 14.0 12.76 5.0 5.2 0.4 2.5
FL2 9.0 16.0 5.0 5.2 0.5 2.5
FL3 1.0 2.0 14.0 4.2 0.5 2.5
FL4 1.0 2.0 8.2 10.0 0.5 2.5
CR1 0.5 16.0 3.5 3.5 0.1 2.5
CR2 1.0 2.0 5.5 10.0 0.5 0
CR3 14.0 0.5 1.0 1.0 0.1 0
CR4 0.5 2.0 16.0 1.0 0.1 0
ML 0.5 1.5 1.0 1.0 0.1 0
--- A
4.1.3. HOLD-UP TIME (@FULL LOAD)
220W:
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
The output voltage will remain within specification, in the event that the input power is removed or
interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any
point in the AC voltage cycle. The power good signal shall remain high during this test.
4.1.4.OUTPUT RISE TIME
(10% TO 90% OF FINAL OUTPUT VALUE, @FULL LOAD)
115V-rms or 230V-rms + 5Vdc : 20ms Maximum
4.1.5.OVER VOLTAGE PROTECTION
Voltage Source Protection Point
+ 3.3 V
dc
3.5V-4.8V
+5V
dc
5.5V-6.82V
+12V1
dc +
+12V2
dc
13.4V-15.6V