Use and Care Manual
5
2
1
10 9 8
7
6
543
Dryer System Monitor
(Models RNP200, RNP250, RNP300, RNP400 and RNP500)
1. On/OffSwitch:Pressthetopoftheswitch(I)toturn
thedryeron.Pressthebottomoftheswitch(O)to
turnthedryeroff.Whenthedryerison,theswitchis
illuminated.
2. ThisisagraphicsymbolfortheAirDryercompressor.
Itsimplyindicatesthattheswitchisusedtoturnthe
compressor(dryer)onandoff.
3. Partofthegraphicforthedewpointtemperature
scale.Thesnowflakeindicatesthelow(cold)endof
the scale.
4. Mainportionofthegraphicforthedewpoint
temperaturescale.Greenindicateslow,orange
indicatesmedium,redindicateshigh.
5. Partofthegraphicforthedewpointtemperature
scale. The thermometer indicates the high (hot) end
ofthescale.
6. Six(6)LEDsthatindicatedewpointtemperature
accordingtothegraphicscaleabovetheLEDs.The
colorofeachLEDmatchesthecoloredbars
7. Adjustmentknobforthedrainvalveopentime.The
values on the dial correspond to the time in seconds
that the valve is open in each drain cycle.
8. Adjustmentknobforthedrainvalveclosedtime.The
values on the dial correspond to the time in minutes
that the valve is closed in each drain cycle.
9. LEDtoindicatewhenthedrainvalveisopen.
10. Draintestbutton.Whenthebuttonispressed,the
drainvalveopensforthetimecorrespondingtothe
settingonitem7.