2.0 Receiving and Installation
A. Receiving
1. Check that your shipment matches your order.
2. Check for any damage that may have occurred during shipment.
B. Installation.
In order to ensure proper installation and trouble free operation with minimal maintenance:
1. Select a location where light is adequate enough to operate, maintain, and inspect the
compressor.
2. A clean, low relative humidity and well-ventilated area is best for safe operation.
The ambient temperature should be kept below 104°F (40). The air delivery of the
compressor will decrease as the temperature gets higher.
3. Reserve space for maintenance, the distance between the compressor and the wall or
other equipment must be greater than 28 inches (71 cm).
4. There must be at least 3 feet of clearance between top of compressor and any over head
obstructions.
5. To avoid damage to the unit, lift using eyebolts and straps as shown in Figure 2.1
Figure 2.1