iCommand-Touch Manual
CAP-837 
Warning message  Remarks 
W033: Speed reduction 
The on "W034: "Speed reduction" programmed digital 
input was opened. Delay 1 s.
W034: Dryer 
The on "W034: Dryer" progr
opened.- 
no delay.
W036: Condensate drain 
The on "W036: "Condensate drain" programmed 
tal input was closed.
W037: Air filter 
The on "W037: "Air filter" programmed digital input 
was closed. Monitoring starts after 15 minutes. Tri
gering of warning without delay.
W038: Oil/oil filter 
The on "W038: "Oil/oil filter" programmed dig
was closed. Monitoring starts after 15 minutes. Tri
gering of warning without delay.
W039: Oil separator 
The on "W039: "Oil separator" programmed digital 
input was closed. Monitoring starts after 15 minutes. 
Triggering of warning without 
W044: Extension module 
At least one of the configured MK200 expansion mo
ules is not answering (possible addresses 8 to 30).
W045: 
I/O-Module (Add.1) 
The analogue output module on address 1 does not 
respond. This monitoring is only active
has been activated.
W046: 
I/O-Module (Add.2) 
The LLC module on address 2 does not respond. This 
monitoring is only active in LLC master operation du
ing digital control of the LLC slave.
W048: 
I/O-Module (Add.4) 
The expansion 
spond. This monitoring is only active, if this module 
has been selected.
W049: 
I/O-Module (Add.5) 
The expansion module on address 5 does not r
spond. This monitoring is only active, if this module 
has been selected.
W050: 
Profib. Mod.(Adr. 31) 
The Profibus module on address 31 does not r
spond. This monitoring is only active, if this module 
has been selected.
iCommand 
52 
Compressor type
The on "W034: "Speed reduction" programmed digital 
input was opened. Delay 1 s.
All 
The on "W034: Dryer" progr
ammed digital input was 
no delay.
All 
The on "W036: "Condensate drain" programmed 
digi-
tal input was closed.
All 
The on "W037: "Air filter" programmed digital input 
was closed. Monitoring starts after 15 minutes. Tri
g-
gering of warning without delay.
All 
The on "W038: "Oil/oil filter" programmed dig
ital input 
was closed. Monitoring starts after 15 minutes. Tri
g-
gering of warning without delay.
All 
The on "W039: "Oil separator" programmed digital 
input was closed. Monitoring starts after 15 minutes. 
Triggering of warning without 
delay. 
All 
At least one of the configured MK200 expansion mo
d-
ules is not answering (possible addresses 8 to 30).
All 
The analogue output module on address 1 does not 
respond. This monitoring is only active
, if this module 
has been activated.
All 
The LLC module on address 2 does not respond. This 
monitoring is only active in LLC master operation du
r-
ing digital control of the LLC slave.
All 
The expansion 
module on address 4 does not re-
spond. This monitoring is only active, if this module 
has been selected.
All 
The expansion module on address 5 does not r
e-
spond. This monitoring is only active, if this module 
has been selected.
All 
The Profibus module on address 31 does not r
e-
spond. This monitoring is only active, if this module 
has been selected.
All 
 iCommand – Touch
iCommand 
- Touch
Compressor type










