Product Manual
Installation and commissioning 
CAP-834  27 
the compressed air hose with high 
force. 
-  Anchor and fasten the compressed 
air hose sufficiently. 
The prerequisite for the correct 
installation is the presence of a 
professionally-planned, installed and 
maintained compressed air network 
and an additional shut-off valve 
installed at the entrance to the 
compressed air network. Relief valves 
are to be placed ahead of any potential 
blockage point, including but not limited 
to shut-off valves, heat exchangers and 
discharge silencers. Always direct 
discharge from relief valves away from 
areas where personnel may be. 
Fig. 24: Discharge porn 
1. 
Connect the compressed air according to the 
technical data (
 Chapter 3 ‘Technical data’   o n 
page 20). 
2. 
Ensure that the compressed air hose does not 
represent a stumbling hazard. 
3. 
Anchor and fasten the flexible compressed air 
hose sufficiently. 
5.3.4  Connecting to the power supply 
Personnel: 
  Qualified Electrician 
NOTICE! 
Property damage to the compressor 
airend due to incorrect connection 
of the power supply! 
In case of incorrect connection of the 
power supply, there is a danger that the 
compressor airend will be destroyed 
due to the drive turning incorrectly. 
-  Connect the power according to the 
wiring diagram and check the 
rotating field before starting the 
screw compressor. 
The prerequisite for the correct 
installation are professionally-
dimensioned fuses in the network 
supply (person/system protection) and 
an appropriate main switch (for 
switching the supply on and off). 
1. 
Using  the  data  in  the  wiring  diagram,  check 
whether the existing supply network is suitable. 
Voltage  deviations  of  more  than  10 %  are  not 
permitted. 
2. 
Connect the power according to the wiring  dia-
gram and the technical data 
 (
 Chapter 3 ‘Technical data’ on page 20). 
3. 
Check  correct  direction  of  rotation  by  briefly 
starting  the  compressor  and  verifying  that  the 
rotation of the machine follows the arrows on the 
main motor and fan motor.  
4. 
Ensure that the power cable does not represent 
a stumbling hazard. 