iCommand Manual
CAP-836 
2.8.1.1  Fault table 
Fault 
no. 
Fault 
abbreviation 
Cause of the fault
61  EProm 
Eprom faulty
63  PAr 
Parameter incorrect
65  no AC 
Power fail
66  SE t 
Temperature sensor faulty
67  SE t2 
Oil liquid temperature sensor 
faulty
68  SE P 
Pressure sensor faulty
70  SE t3 
Cable definition dew point 
temperature (if additional 
module MK200
71  EmErG 
Emergency stop pressed
72  rotAt 
Direction of rotation
motor incorrect
73  Mot t 
Motor temperature too high
74  hiCur 
Ventilator flow too high
75  hi Pr 
Network pressure too high
77  hi t 
Compressor temperature too 
high 
78  hi P 
Network pressure too high
iCommand 
31 
Cause of the fault
  Fault remedy 
Eprom faulty
  Replace controller 
Parameter incorrect
Check and change pressure set 
points 
Power fail
  Check power supply 
Temperature sensor faulty
Check cabling of temperature 
sensor/replace temperature 
sensor 
Oil liquid temperature sensor 
Check 
cabling of oil liquid 
temperature sensor/Replace oil 
liquid temperature sensor
Pressure sensor faulty
Check cabling for pressure 
sensor/replace pressure sensor
Cable definition dew point 
temperature (if additional 
module MK200
-4AE4R) 
Check cabling of dew point 
sensor/as necessary Replace 
dew point sensor 
Emergency stop pressed
Eliminate cause of emergency 
stop 
Direction of rotation
 of the 
motor incorrect
Set correct direction of rotation 
of the motor 
Motor temperature too high
  Let motor cool off 
Ventilator flow too high
  Check ventilator flow 
Network pressure too high
  Reduce network pressure
Compressor temperature too 
Let compressor cool off 
Network pressure too high
  Reduce network pressure
iCommand 
- Basic 
Personnel 
Qualified 
electrician 
Check and change pressure set 
Trained 
person 
Qualified 
electrician 
Check cabling of temperature 
sensor/replace temperature 
Qualified 
electrician 
cabling of oil liquid 
temperature sensor/Replace oil 
Qualified 
electrician 
Check cabling for pressure 
sensor/replace pressure sensor
Qualified 
electrician 
Check cabling of dew point 
sensor/as necessary Replace 
Qualified 
electrician 
Eliminate cause of emergency 
Trained 
person 
Set correct direction of rotation 
Qualified 
electrician 
Trained 
person 
Qualified 
electrician 
Trained 
person 
Trained 
person 
Trained 