Product Manual

MASTERLINE SERIES CAP200
Page 33 of 46 REV H JUNE 2017
Low Oil Guard
(D96, C79, D97, C89, C98)
To help prevent catastrophic damage, FS Curtis provides an option for a Low Oil Guard, which
prevents the unit from starting when the oil level has dropped below the low oil mark on the
sight glass or dipstick, see Fig (12) for proper oil level. FS Curtis’s low oil guard utilizes a
magnetic float switch. The low oil guard is rated for 300VAC MAXIMUM. Applications with
higher voltages will require the use of a control power transformer.
CAUTION!
A low oil guard is not a substitution for proper maintenance. Continue to perform
regular oil changes at intervals stated in this manual.
WARNING!
Never assume a compressor is safe to work on just because it is not currently
operating. It could restart at any time. Follow all safety precautions outlined in the
Safety Precautions section. Turn off and lockout/tagout the main power disconnect
switch before attempting to perform maintenance on the unit.
1
PARTS LIST - LOW OIL GUARD NEW DESIGN
ITEM # DESCRIPTION QTY PART #
1 10-32 x 1/2 FILLISTER HEAD SCREW 8 VH03CD
2 LOW OIL SWITCHPLATE COVER 1 CM1074
3 WASHER-ALUMINUM 9/16 X 25/64 X 0.051 1 VH1232
4 LOW OIL SWITCH PLATE 1 CM1072
5 O-RING 1/16" X 2.364 ID DUROMETER 1 VB418
6 LOW OIL MAGNETIC FLOAT 1 CM1073
7
CONNECTION-COMP. STRAIGHT SLEEVE AND
NUT 1/8 X 1/4
1 VA14ACE
8 LOW OIL FLOAT HOUSING 1 CM1070
9 PLUG- SQUARE HEAD-STEEL 1/2" 1 VA01DR
2
3
4
5
6
8
7
9
Fig (13) Low oil Guard exploded assembly