Product Manual
MASTERLINE SERIES CAP200
Page 11 of 46 REV H JUNE 2017
Fig (6) Large Industrial Base Mount Fig (7) Masterline Base Mount
MODEL
DIMENSION (INCHES)
Weight
MODEL
DIMENSION (INCHES)
Weight
A
B
C
(lb)
A
B
C
(lb)
D96
25.75
n/a
17.375
350
C150H
64.75
32.375
20
2700
C79
25.75
n/a
17.375
400
C200
64.75
32.375
20
3000
D97
25.75
n/a
17.375
675
C200S
64.75
32.375
20
3000
C89
25.75
n/a
17.375
775
C260H
64.75
32.375
20
3000
C98
37-5/8
18-13/16
25-1/4
1250
C260
64.75
32.375
20
3000
CWT98
65-1/2
32-3/4
25-1/4
1700
C300
76
38
27.75
5000
C100
64.75
32.375
20
2700
C300S
76
38
27.75
5000
C100S
64.75
32.375
20
2700
C300H
76
38
27.75
5000
Table (2) Foundation Dimensions
NOTE: Consult a qualified civil engineer for required concrete thickness and / or supports
Acceptable Mounting
Unacceptable Mounting
Concrete Anchor Bolts
Threaded Rod or Floor Stud
Steel flooring or supports (provided unit
is bolted down and isolator pads are
used)
Skid Mounted
Unanchored
Bare Floor (no vibration pads)
Table (3) Compressor mounting methods
If you wish to utilize an installation method other than the approved methods described in
Table (2), please contact your local distributor. FS Curtis neither states as fact, nor implies
that the above list of Acceptable/Unacceptable mounting is all-inclusive. Contact your local
distributor for more information.