Troubleshooting 
Problem  Cause  Remedy 
1 
Unit won’t start 
•  Power not on 
•  Fuse blown 
•  Low voltage supplied 
•  Worn pressure switch contacts 
•  Starter overload tripped 
•  Broken / loose electrical 
connections 
•  Check breaker and / or disconnect 
•  Replace the fuse or disconnect 
•  Contact distributor 
•  Replace 
•  Reset starter overload 
•  Check electrical connections 
2 
Flywheel / motor 
rotating clockwise 
•  Incorrect lead connection  •  Reverse the leads 
3 
Flywheel /motor 
rotating slowly 
•  Excessively dirty oil 
•  Heavy lubrication oil 
•  Oil thick due to low temperature 
•  Belt slipping 
•  Incorrect voltage 
•  Change the oil 
•  Use correct oil 
•  Increase ambient temperature above 
40°F 
•  See 6 
•  Contact distributor 
4 
Excessive 
V
ibrations 
•  Vibration pads not installed 
•  Unit not leveled 
•  Unit not securely fastened 
•  Install vibration pads 
•  Level unit with metal shims 
•  Check for loose bolts on foundation, 
compressor, and motor 
5 
Compressor 
overheats 
• Ambient air temperature too high 
• Degraded oil 
• Incorrect oil 
• Clogged Air Intake 
• Interior or exterior fouling of the 
intercooler 
• Ensure adequate ventilation 
• Change oil 
• Use correct oil 
• Replace filter and clean intake 
• Clean intercooler 
6 
Belt slipping 
• Working pressure too high 
• Low belt tension 
• Worn belt 
• Incorrect belt 
• Worn or misaligned pulley 
• Lower working pressure 
• Adjust belt tension 
• Replace 
• Install correct belt 
• Replace or align pulley 