Use and Care Manual
MAINTENANCE /
REPAIR
TROUBLESHOOTINGOPERATION
SAFETY /
SPECIFICATIONS
GETTING STARTED
7
ASSEMBLY /
INSTALLATION
INSTALLATION INSTRUCTIONS
Disconnect, tag and lock out power source then release all pressure
from the system before attempting to install, service, relocate or perform any
maintenance.
Do not lift or move unit without appropriately rated equipment. Be sure the unit is
securely attached to lifting device used. Do not lift unit by holding onto tubes or
coolers. Do not use unit to lift other attached equipment.
Picking the Location
Install and operate unit at least 18 inches from any obstructions in a
clean, well ventilated area. The compressor must be placed on a firm
surface. The surrounding air temperature should not exceed 100° F.
This will ensure an unobstructed flow of air to cool compressor and
allow adequate space for maintenance.
Do not locate the compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination. This debris will damage
the motor.
NOTE: If compressor operates in a hot, moist environment, supply
compressor pump with clean, dry outside air. Supply air should be
piped in from external sources.
Electrical Installation
All wiring and electrical connections
should be performed by a qualified
electrician. Installation must be in accordance with local
codes and national electrical codes.
Wiring
1. Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for
at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this
minimum.
2. Use a slow blow fuse or a circuit breaker.
3. This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated in Figure 3.
Make sure the product is connected to an outlet having the same
configuration as the plug. This product must be grounded. In the
event of an electrical short circuit, grounding reduces risk of electrical
shock by providing an escape wire for electric current. This product
is equipped with a cord having a grounding wire with an appropriate
grounding plug. Plug must be plugged into an outlet that is properly
installed and grounded in accordance with all local codes and
ordinances.
Overheating, short circuiting and fire damage will result from inadequate wiring.
Amp
Rating
Range
Voltage Cord Length in Feet
120V 25 ft. 50 ft. 100 ft. 150 ft. 200 ft. 250 ft. 300 ft. 400 ft. 500 ft.
240V 50 ft. 100 ft. 200 ft. 300 ft. 400 ft. 500 ft. 600 ft. 800 ft. 500 ft.
8 - 10 14108666442
10 - 12 12108664422
12 - 14 1288664420
14 - 16 1288444220
≥ 18
inches
≥ 18
inches
≥ 18
inches
Figure 2 - Location
TEST
RESET
Figure 3 - Grounding Method
Grounded Outlet
Grounding Pin