Use and Care Manual
CA / CT SERIES CAP600
Page 27 of 30 REV E JULY 2014
Troubleshooting
Problem
Cause
Remedy
1
Unit won’t start
Power not on
Fuse blown
Low voltage supplied
Worn pressure switch contacts
Starter overload tripped
Broken / loose electrical
connections
Check breaker and / or disconnect
Replace the fuse or disconnect
Contact distributor
Replace
Reset starter overload
Check electrical connections
2
Flywheel / motor
rotating clockwise
Incorrect lead connection
Reverse the leads
3
Flywheel /motor
rotating slowly
Excessively dirty oil
Heavy lubrication oil
Oil thick due to low temperature
Belt slipping
Incorrect voltage
Change the oil
Use correct oil
Increase ambient temperature above
40°F
See 6
Contact distributor
4
Excessive
Vibrations
Vibration pads not installed
Unit not leveled
Unit not securely fastened
Install vibration pads
Level unit with metal shims
Check for loose bolts on foundation,
compressor, and motor
5
Compressor
overheats
Ambient air temperature too high
Degraded oil
Incorrect oil
Clogged Air Intake
Interior or exterior fouling of the
intercooler
Ensure adequate ventilation
Change oil
Use correct oil
Replace filter and clean intake
Clean intercooler
6
Belt slipping
Working pressure too high
Low belt tension
Worn belt
Incorrect belt
Worn or misaligned pulley
Lower working pressure
Adjust belt tension
Replace
Install correct belt
Replace or align pulley