Trouble shooting for DA Series
Problem:
Heavy air flow from one or both of the DA Exhaust ports (mufflers)
NOTE: Alternating “light” air flow from exhaust port (Muffler) is normal as this presents the
regeneration cycle.
Possible Cause
Remedy
Worn purge valve or dirt/ foreign material
is stuck in the purge valve
Clean cavities and replace purge valve
assembly Part # 619702
Worn inlet check valve
Clean cavity replace valve assembly Part
# 619702
Problem:
DA Series cycle will not alternate every two minutes
Possible Cause
Remedy
Micro Logic Timer (MLT) malfunctioning
Contact FSCurtis Customer Service
Or a local distributor at 314-383-1300
Air Control valve malfunctioning
Replace Air Control valve part # 619755
Air Line tubing connecting air control
valve and valve housing and/or manifold
damaged or missing
Replace / Repair air line or tubing
Problem:
Safety Valve opens
Possible Cause
Remedy
Safety Valve Malfunctioning
Replace safety valve part # 619740
200psi
System pressure setting exceeds safety
valve setting (200psi)
Reduce system operating pressure