Product Manual

CAP820
REV B
MARCH, 2017
1
DA Series Installation instructions
Warning: Before proceeding with installation read and observe following safety
precautions.
1. Read entire instruction sheet before beginning installation of the DA Series.
2. Never connect or disconnect a pipeline/line containing air pressure or remove a
component ,fitting or pipe plug unless you are certain all air pressure has been
exhausted.
3. Always wear proper eye protection when installing or servicing DA Series. Never
look directly into ports of the DA Series.
4. Never exceed recommended working air pressure of 175 PSIG
5. Optimum working pressure 100 to175 PSIG.
6. Never attempt to install or service DA Series until you read and understand all
recommended procedures.
7. Use only proper tools and observe all procedures pertaining to the use of those
tools.
Basic mounting guidelines
1. The DA Series must be mounted with the exhaust ports positioned downward.
(Ref. Fig 1.)
2. Power source: 110-120 Volt AC (grounded) electric receptacle required (surge
protection required) for operation of DA Series.
3. Mount DA Series downstream of air compressor reservoir ( Ref. Fig 1 )
4. The DA Series should be mounted in a location with sufficient space around it to
facilitate service and to provide visual access for a periodic inspection. Allow at
least two (2.00) inch clearance above desiccant cartridges for service.
5. Consider installing a series of lines and shut-off valves in conjunction with the
installation of the DA Series to provide a by-[pass system of the DA Series. Doing
so will provide ability to maintain operation of air system, while future service of the
DA Series is being performed.