Specifications Sheet
RE Electric Fryers
Model #_______________
CSI Section 11400
8700 Line Avenue
Shreveport, LA 71106-6800
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@frymaster.com
www.frymaster.com
Bulletin No. 818-0468
Revised 2/13/15
Litho in U.S.A. ©Frymaster
MODEL NO.
OIL
CAPACITY
OVERALL SIZE (cm)
NET
WEIGHT
DRAIN
HEIGHT
SHIPPING INFORMATION
WIDTH DEPTH HEIGHT WEIGHT CLASS CU. FT. DIMENSIONS (cm)
RE14/17/22
RE14/TC/17TC/22TC
RE14-2/17-2/22-2
RE14-2TC/17-2TC/22-2TC
50 lb
(25 liter)
25 lb.
(12 liter)
15-5/8”
(39.7)
31”*
(78.6)
45-3/8”*
(115.2)
150 lbs.
(68 kg)
11-7/8”
(29.9 cm)
190 lbs.
(86 kg)
85 21.31
W
22”
(55.9)
D
36”
(91.4)
H
46-1/2”
(118.1)
DIMENSIONS
POWER REQUIREMENTS
HOW TO SPECIFY
The following description will assist with ordering the
features desired:
RE14 14 kw full frypot, analog controller
RE14TC 14 kw full frypot, triac controls, CM3.5 controller
RE14-2 14 kw split frypot, analog controller
RE14-2TC 14 kw split frypot, triac controls, CM3.5 controller
RE17 17 kw full frypot, analog controller
RE17TC 17 kw full frypot, triac controls, CM3.5 controller
RE17-2 17 kw split frypot, analog controller
RE17-2TC 17 kw split frypot, triac controls, CM3.5 controller
RE22 22 kw full frypot, analog controller
RE22TC 22 kw full frypot, triac controls, CM3.5 controller
RE22-2 22 kw split frypot, analog controller
RE22-2TC 22 kw split frypot, triac controls, CM3.5 controller
NOTES
• TC models not available in 480V.
• One cord is provided per full and dual split frypot on 3
phase 14 kw and 17 kw models.
• Cord is provided on 3 phase units with exception of items
in red (see chart on left).
• Plug is optional accessory on units shipping with cord.
Canada is an exception and cords, where available, must
have a plug attached.
• Optional plug -- (Domestic NEMA # 15-60P).
• All 22 kw and single phase units must be eld wired. No
cord or plug provided. Check electrical codes for proper
supply line sizing.
• Controller, filter pump and basket lifts are powered by
element voltages except for 480V fryers.
• All 480 volt models are provided with separate 120 volt
cord and plug for lter pump, and/or controller, and/or
basket lifts.
CLEARANCE INFORMATION
A minimum of 24” (61 cm) should be provided at the front
of the unit for servicing and proper operation, 6” (15.2 cm)
between the sides and rear of the fryer to any combustible
material.
15.6
[397]
45.3
[1149]
25.9
[657]
36.6
[929]
31.0
[786]
14.1
[358]
CORDSET
LOCATION
3.7
[95]
CORDSET
LOCATION
8.3
[212]
TOP VIEW
FRONT VIEW SIDE VIEW BACK VIEW
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Check www.frymaster.com for updates.
*without basket lifts
BASIC
DOMESTIC
kw
ELEMENTS/FRYPOT
CONTROLS/
FRYPOT
BASKET
LIFTS/
FRYPOT
VOLTAGE
3
PHASE*
1
PHASE**
RE14
RE14TC***
14
208V
240V
480V
39 A
34 A
17 A
67 A
58 A
N/A
1 A
1 A
120V 1 A
2 A
2 A
120V 3 A
RE14-2
RE14-2TC***
7
RE17
RE17TC***
17
208V
240V
480V
48 A
41 A
21 A
82 A
71 A
N/A
1 A
1 A
120V 1 A
2 A
2 A
120V 3 A
RE17-2
RE17-2TC***
8.5
RE22
RE22TC***
22
208V
240V
480V
61 A
53 A
27 A
106 A
92 A
N/A
1 A
1 A
120V 1 A
2 A
2 A
120V 3 A
RE22-2
RE22-2TC***
11
BASIC EXPORT
& CE
RE14
RE14TC
14
220V/380V
230V/400V
240V/415V
250/430V****
22 A
21 A
20 A
20 A
N/A
1 A
1 A
1 A
1 A
2 A
2 A
2 A
2 A
RE14-2
RE14-2TC
7
RE17
RE17TC
17
220V/380V
230V/400V
240V/415V
250/430V****
26 A
25 A
24 A
25 A
N/A
1 A
1 A
1 A
1 A
2 A
2 A
2 A
2 A
RE17-2
RE17-2TC
8.5
RE22
RE22TC
22
220V/380V
230V/400V
240V/415V
250/430V****
34 A
32 A
31 A
32 A
N/A
1 A
1 A
1 A
1 A
2 A
2 A
2 A
2 A
RE22-2
RE22-2TC
11
*3 PH/3 Wire/Plus Ground Wire.
**1 PH/2 Wire/Plus Ground Wire.
***TC models not available in 480V.
**** Australia filter models only -- when operating at 250V, elements will be rated at
approximately 15.2/18.5/23.9 kw.