Specifications Sheet

LHD65 Large Vat Gas Fryer
Model #_______________
CSI Section 11400
8700 Line Avenue
Shreveport, LA 71106-6800
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@frymaster.com
www.frymaster.com
Bulletin No. 818-0730
Revised 1/20/15
Litho in U.S.A. ©Frymaster
MODEL
NO.
OVERALL SIZE (cm)
DRAIN
HEIGHT
(cm)
SHIPPING INFORMATION
WIDTH DEPTH HEIGHT WEIGHT CLASS CU. FT.
DIMENSIONS (cm)
W D H
LHD165
20”
(50.8)
36-1/4”
(92.1)
43”
(109.2)
12-1/2”
(317.5)
260 lbs.
(118 kg)
77.5 72.9
53”
(134.6)
44”
(111.8)
54”
(137.2)
FPLHD265
40”
(101.6)
36-1/4”
(92.1))
43”
(109.2)
12-1/2”
(317.5)
750 lbs.
(340 kg)
77.5 72.9
53”
(134.6)
44”
(111.8)
54”
(137.2)
FPLHD365
60”
(152.4)
36-1/4”
(92.1)
43”
(109.2)
12-1/2”
(317.5)
1100 lbs.
(499 kg)
77.5 82.5
70”
(177.8)
44”
(111.8)
54”
(137.2)
FPLHD465
80”
(203.2)
36-1/4”
(92.1)
43”
(109.2)
12-1/2”
(317.5)
1400 lbs.
(635 kg)
77.5 122.4
86”
(218.4)
44”
(111.8)
54”
(137.2)
FPLHD565
100”
(254.6)
36-1/4”
(92.1)
43”
(109.2)
12-1/2”
(317.5)
750/1100 lbs
(340/499 kg)
2 crates
77.5
72.9
82.5
53”
(134.6)
70”
(177.8)
44”
(111.8)
54”
(137.2)
FPLHD665
120”
(304.8)
36-1/4”
(92.1)
43”
(109.2)
12-1/2”
(317.5)
750/1400 lbs.
(340/635 kg)
2 crates
77.5
72.9
122.4
53”
(134.6)
86”
(218.4)
44”
(111.8)
54”
(137.2)
The FPLHD565 and FPLHD665 are shipped in two crates In-field installation required.
DIMENSIONS
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
Check www.frymaster.com for updates.
NOTES:
1-1/2” (3.8 cm) kitchen main manifold
gas supply line required. Gas inlet size
(I.D.) should be no smaller than that
provided for connection to the fryers. See
service manual and/or plumbing codes
for proper pipe sizing. Recommended
minimum store manifold pressure to
be 6” W.C. for natural gas and 11” W.C.
for L.P. gas. Check plumbing codes for
proper supply line sizing to attain burner
manifold pressure of 3.0” W.C. natural or
8.25” W.C. L.P.
POWER CORDS: On 1 and 2 battery units,
1 power cord supplied
On 3 and 4 battery units, 2 power cords
supplied
On 5 and 6 battery units, 3 power cords
supplied
DO NOT CURB MOUNT
CLEARANCE INFORMATION
A minimum of 24” (61.0 cm) should be
provided at the front of the unit for ser-
vicing and proper operation, and 6” (15.2
cm) between the sides and rear of the
fryer to any combustible material.
POWER REQUIREMENTS:
The following description will assist
with ordering the features desired for
this equipment:
LHD165 Single high-volume, low
flue temperature gas
fryer, 105,000 Btu/hr, 3000
controller and casters
FPLHD265 Battery of 2 high-volume,
low flue temperature gas
fryers, 105,000 Btu/hr, 3000
controllers
FPLHD365 - Battery of 3 high-volume,
low flue temperature gas
fryers, 105,000 Btu/hr with
space-saving under fryer
filter, 3000 controllers, and
casters.
Please specify gas type.
HOW TO SPECIFY  EXAMPLES
WASHDOWN/
OIL DISPOSAL
CONNECTION
(2 PLACES)
(3) POWER
CORDS
39.500[1003mm]
36.250[921mm]
(5) SPLASH GUARDS AND (1) S/S
BASKET HANGERS WITH DEFLECTOR
36.000[914mm]
11" TOPCAP/WORK AREA
(1°-2° TILT TOWARD FRYPOT)
11.50" REF
43.00[1092mm]
1-1/2" DRAIN VALVE
(6 PLACES)
DRAIN FLUSH
(BOTH ENDS)
3" DRAIN
SYSTEM
20.00[508mm]
40.00 [1016 mm]
20.00[508mm]
120.00[3048mm]
18" X 18"
COOKING AREA
(6) 65 POTS
8.50" REF
FPHD65 FILTER PAN ASSY WITH
CRUMB BASKET, SCREEN, AND
HOLD DOWN RING FOR FILTER PAPER
S/S POT DIVIDERS WITH TWO PINS
(2) 1-1/4 NPT 1-PIECE MANIFOLDS PLUG ONE
END, 1-1/4 X 1" BUSHING ONE END (MAX.
LENGTH OF 1-1/4" HOSE CONNECTION 4FT.)
20.00[508mm]
20.00[508mm]
NOTE: UNIT ASSEMBLY BREAKS AT THE 265/465
INTERFACE FOR SHIPPING AND HANDLING.
1.23[31mm]
2.00
[50.8mm]
5.00
[127mm]
120V ACCESSORY RECEPTACLE W/CORD
Filter locations vary depending on number of fryers in the battery
2 battery -- filter located under both fryers
3 battery -- filter located under fryers #1 and 2 (left to right)
4 battery -- filter located under fryers #2 & 3 (left to right)
5 battery -- filter located under fryers #2 & 3 (left to right)
6 battery -- filter located under fryers #3 & 4 (left to right)
LHD65 Gas Connection Requirements
Model Gas Connection Size
LHD165 One 3/4”
FPLHD265 One 1”
FPLHD365 One 1”
FPLHD465 One 1-1/4”
FPLHD565 Two 1”
FPLHD665 One 1” and One 1-1/4”
MODEL NO.
OPTIONS DOMESTIC
CONTROLS/
FRYPOT
FILTER
LHD165 120V 1 A N/A
FPLHD265/FPLHD365/
FPLHD465/FPLHD565/FPLHD665
120V 1 A 120V 8 A
OPTIONS EXPORT
LHD165
220V 1A
230V 1 A
250V 1 A
N/A
FPLHD265/FPLHD365/
FPLHD465/FPLHD565/FPLHD665
220V 1A 220V 4A
FPLHD265/FPLHD365/
FPLHD465/FPLHD565/FPLHD665
230V 1 A 230V 4 A
FPLHD265/FPLHD365/
FPLHD465/FPLHD565/FPLHD665
250V 1 A 250V 4 A