Specifications Sheet

OCF30ATOG Ultimate Oil-Conserving Gas Fryers -- Domestic & Export
Model #_______________
CSI Section 11400
8700 Line Avenue
Shreveport, LA 71106-6800
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@frymaster.com
www.frymaster.com
Bulletin No. 818-0657
Revised 1/27/15
Litho in U.S.A. ©Frymaster, LLC
DIMENSIONS
CORDSET
TOP VIEW
FRONT VIEW
SIDE VIEW
DIMENSIONS
INCHES
MM
29.8
[757]
8.3
[212]
36.5
[927]
10.1
[257]
PAN LID
HEIGHT
-A-
BATTERYINMM
2
3
4
5
31.3
47.1
62.5
78.2
795
1195
1587
1986
CHART
FRYER WIDTH
-A-
48.8
[1238]
FILTER PAN
REMOVAL
12.5
[316]
21.6
[549]
11.5
[291]
6.2
[158]
1" NPT GAS
CONNECTION
BACK VIEW
6.5
[165]
17.3
[439]
CORDSET LOCATION
46.5
[1182]
We reserve the right to change specications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold. Check www.frymaster.com for
updates.
MODEL NO.
OIL
CAPACITY
OVERALL SIZE (cm)
NET
WEIGHT
SHIPPING INFORMATION
WIDTH DEPTH HEIGHT WEIGHT CLASS CU. FT. DIMENSIONS (cm)
FPGL230CA
FPGL230CA SPLIT
30 lbs.
(15 liters)
Full Frypot
17 lbs.
(8.5 liters)
Split Frypot
31-1/4”
(79.5)
29-7/8”
(75.7)
46-1/2”
(118.2)
500
(227 kg)
544
(247 kg)
77.5
52.84
W
38”
(96.5)
D
44”
(111.8)
H
53”
(134.6)
FPGL330CA
FPGL330CA SPLITS
47-1/8”
(119.5)
675
(306 kg)
723
(328 kg)
74.39
53-1/4”
(135.9)
53”
(134.6)
FPGL430CA
FPGL430CA SPLITS
62-1/2”
(158.7)
858
(390 kg)
908
(412 kg)
100.12
72
(182.9)
55”
(139.7)
FPGL530CA
FPGL530CA SPLITS
78-1/4”
(198.6)
1,039
(471 kg)
1,077
(489 kg)
116 86”
55”
(139.7)
NOTES
5 ft. (1.5 m) grounded cord set provided on Domestic fryers.
8 ft. 10 “ (2.7 m) grounded cord set provided on Export/CE fryers.
1-1/2” (3.8 cm) kitchen main manifold gas supply line required.
Gas inlet size (I.D.) should be no smaller than that provided for
connection to the fryers. See service manual and/or plumbing
codes for proper pipe sizing. Recommended minimum store
manifold pressure to be 6” W.C. for natural gas and 11” W.C. for L.P.
gas. Check plumbing codes for proper supply line sizing to attain
burner manifold pressure of 3.0” W.C. natural or 8.25” W.C. L.P.
Natural gas only for New Zealand.
DO NOT CURB MOUNT
CLEARANCE INFORMATION
A minimum of 24” (61.0 cm) should be provided at the front of
the unit for servicing and proper operation, and 6” (15.2 cm) be-
tween the sides and rear of the fryer to any combustible material.
POWER REQUIREMENTS
MODEL
NO.
BASIC DOMESTIC/EXPORT
OPTIONS
DOMESTIC/EXPORT
CONTROLS/
FRYPOT
FILTER
AUTO TOP
OFF/FRYPOT
BASKET LIFTS/
FRYPOT
FPGLCA
120V 1 A
220V 1 A
230V 1 A
240V 1 A
250V 1 A
120V 8 A
220V 5 A
230V 5 A
240V 5 A
250V 5 A
120V 1 A
220V 1 A
230V 1 A
240V 1 A
250V 1 A
120V 3 A
220V 2 A
230V 2 A
240V 2 A
250V 2 A
Available for natural gas, propane, butane and any LP gas combination (butane
and LP combinations not CSA or AGA approved).
Liter conversions are for liquid shortening @ 70° F.
Contact Customer Service at 1-800-221-4583 inside USA; +1-318-865-1711 outside USA.
HOW TO SPECIFY
FPGL30CA High-eciency, oil-conserving, 30-lb.
open frypot (full or split) gas fryer with
Auto Top- O, 3000 controller, built-in
ltration, casters and stainless steel
frypot, door, and cabinet sides.
FP = Built-in lter: FM represents
built-in lter with spreader
X = Number of frypots (1-4)
30 = 30-lb. oil capacity
C = Controller
-Y = Split frypot(s) (-2 to -8)
Z = Position of split frypot (L = left,
C = center, R = right)
A = Auto Top O
BL = Basket lifts
MODEL NO. EXPLANATION: FPGLX30CA & FPGLX30-YZCA
OCF30ATOG Gas Connection
Requirements
No. of Fryers
Gas Connection
Size
2 - 4 One 1”
5 Two 1
For Germany 1/2” NPT Per
Frypot