6-4
6.2.3 Basket Lift Problems
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Basket lift movement is
jerky and/or noisy.
Basket lift rods need
lubrication.
Apply a light coating of Lubriplate
or similar
lightweight white grease to the rod and bushings.
6.2.4 Filtration Problems
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Fryer filters after
each cook cycle.
Filter prompt setting incorrect. Change the filter prompt setting.
Filter menu functions
won’t start.
Temperature too low or controller
displays OFF.
Ensure fryer is at setpoint before starting; ensure
the controller is ON.
Controller displays
WAIT FOR
Filter.
Another function is still in process.
Wait until the previous function ends to start
another filtration cycle.
Filter pump won’t
start or pump stops
during filtering.
A. Power cord is not plugged in or
circuit breaker is tripped.
B.
Pump motor has overheated
causing the thermal overload
switch to trip.
C. Blockage in filter pump.
A. Verify that the power cord is fully plugged in
and the circuit breaker is not tripped.
B. If the motor is too hot to touch for more than
a few seconds, the thermal overload switch
has probably tripped. Allow the motor to
cool at least 45 minutes then press the Pump
Reset Switch (see page 4-3).
C. Call your FAS for assistance.
Filter Pump runs, but
oil return is very
slow.
Improperly installed or prepared
filter pan components or cold oil.
Remove the oil from the filter pan and replace
the filter paper, ensuring that the filter screen is
in place under the paper.
Verify that O-rings are present and in good
condition on filter pan connection fitting.
Controller displays
OIL IN DRAIN
PAN / CONFIRM
Drain valve open or possibility that
oil is in drain pan.
Press (CONFIRM) and follow directions for
FILL VAT FROM DRAIN PAN.
6.2.5 Auto Top-Off Problems
PROBLEM PROBABLE CAUSES CORRECTIVE ACTION
Frypots top off cold.
Incorrect setpoint. Ensure setpoint is correct.
Frypots won’t top off.
A. Fryer temperature too low.
B. Oil is too cold.
C. JIB out of oil
D.
Crumb build up around
sensor”
E. Service required error exists
A. Fryer temperature must be at setpoint.
B. Ensure that the oil in the JIB is above 70°F
(21°C).
C. Ensure the JIB is not out of oil and supply
line is in the JIB. Replace JIB and press the
button when prompted to reset top off
system.
If problem persists c
all your FAS for
assistance.
D. Clean crumbs from opening surrounding
sensor.
E. Call your FAS for assistance.