Owners Manual

Table Of Contents
2-6
* For distances of more than 20 feet (6 m) and/or more
than 4 fittings or elbows, increase the connection by one
pipe size.
The OCF30
Series gas fryer has received the CE mark for the countries and gas categories
indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU
and category 3P/B, which is 23kW.
NOTICE- Australia Only
The air pressure switch on the combustion blower should read: Full Vat units-122pa
(0.5 inches W.C.) and for Split Vat units-180pa (0.72 inches W.C.).
COUNTRIES CATEGORIES GAS PRESSURE (MBAR)
AUSTRIA (AT) II2H3B/P
G20 20
G30, G31 50
BELGIUM (BE)
I2E(R)B G20, G25 20, 25
I3+ G30, G31 28-30, 37
DENMARK (DK) II2H3B/P
G20 20
G30, G31 30
FRANCE (FR)
II2Esi3+
G20, G25 20, 25
G30, G31 28-30, 37
II2Esi3P
G20, G25 20, 25
G31 50
FINLAND (FI) II2H3B/P
G20 20
G30, G31 30
GERMANY (DE)
II2ELL3B/P
G20, G25 20
G30, G31 50
I3P G31 50
GREECE (GR) II2H3+
G20 20
G30, G31 28-30, 37
ITALY (IT) II2H3+
G20 20
G30, G31 28-30, 37
IRELAND (IE) II2H3+
G20 20
G30, G31 28-30, 37
LUXEMBOURG (LU) II2E3B/P
G20 20
G30, G31 50
NETHERLANDS (NL)
II2L3P
G25 25
G31 50
II2L3B/P
G25 25
G30, G31 30
NORWAY (NO) I3B/P G30, G31 30
PORTUGAL (PT) II2H3+
G20 20
G30, G31 28-30, 37
SPAIN (ES)
II2H3+
G20 20
G30, G31 28-30, 37
II2H3P
G20 20
G31 37, 50
SWEDEN (SE) II2H3B/P
G20 20
G30, G31 30
UNITED KINGDOM (UK) II2H3+
G20 20
G30, G31 28-30, 37
CE Standard
Required airflow for the combustion air supply is 2m
3
/h per kW.
1. Connect the quick-disconnect hose to the fryer quick-disconnect under the fryer and to the
building gas line.
CE Approved Gas Categories by Country