3000 Controller
Table Of Contents
1-5
1.4 Vat Setup cont.
Left Display Right Display Action
Product Setup
Blank
Press to scroll to Vat setup and press .
Vat setup Enter code
Enter 1656.
SYSTEM
Blank
Press to scroll to FILTER.
filter
Blank
Press .
Cooks til Filter
0
Press . (This is the total number of cooks that occur before a filter prompt. The
default is 0.) Enter the number of cooks before a filter prompt is desired.
EOD FILTER TIMER DISABLED
Press to scroll to choice enable or disable and press . Default is
DISABLED)
Eod filter time 23:59
Use numbered keys to program end of day filter alert time. Enter time in 24 hour
format. Press . Enter 23:59 if no end of day filter prompt is desired. After this
time, the controller prompts for filter when user presses the power button to go to
the OFF state.
FLUSHING TIMER 5
Use numbered keys to change default setting for the flushing timer in Clean and
Filter. Enter the time in minutes. Default is five minutes.
Boil out timer 30
Use numbered keys to change default setting for the boil out timer. Enter the time in
minutes. Default is 30 minutes.
1 polish TIMER DISABLED
Press to scroll to choice enable or disable and press . Default is
DISABLED)
1 polish prompt
time
23:59
Use numbered keys to program polish prompt time. Press . (This is the time the
polish prompt will occur each day.) Enter time in 24 hour format.
1 polish duration
15
Use numbered keys to change. Press . (This is the duration, in minutes for a
polish.) Default to 15 minutes.
1 polish start
TEMPR
(300F) (149°C)
Use numbered buttons to change temperature. (This is the minimum temperature
required for a polish to begin.) Press . Default is 300F (149C).
Exit Exit
Press button once and press to scroll to System, Time/Date, Filter, E-Log or
Change Password. With desired choice displayed, press
or press the Exit/Scan
button once to return the controller to OFF.
E-LOG
Follow the first three steps above to adjust time and date.
OFF OFF
Press until the controller displays Main Menu for three seconds changing to
PRODUCT SETUP.
Product Setup
Blank
Press to scroll to Vat setup and press .
Vat setup Enter code
Enter 1656.
SYSTEM
Blank
Press to scroll to E-LOG.
E-Log
Blank
Press . (This is a log of the ten most recent error codes.)
NOW Time/date
Press . (Current time and date)
A
E#
Time/date
Errors listed A-J. Press to scroll through errors. Error codes are listed on page 7-
5. If no errors exist, pressing will display No errors.
Exit Exit
Press button once and press to scroll to System, Time/Date, Filter, E-Log or
Change Password. With desired choice displayed, press
or press the Exit/Scan
button three times to return the controller to OFF.
Change password
Blank
Press .
Product setup
1650
Use numbered keys to change code. Press .
Vat setup
1656
Use numbered keys to change code. Press .
Exit Exit
Press button once and press to scroll to System, Time/Date, Filter, E-Log or
Change Password. With desired choice displayed, press
or press the Exit/Scan
button three times to return the controller to OFF.