2.5 Converting to Another Gas Type
This equipment is configured at the factory for either natural gas or LP (propane) gas.
If you desire to switch from one type of gas to the other, a gas conversion kit must be installed by a
Factory Authorized Service Center technician.
DANGER
Switching to a different type of gas without installing the proper conversion kit may
result in fire or explosion! NEVER attach your fryer to a gas supply for which it is
not configured.
2.6 Boil-Out Instructions
CAUTION
Do not leave rethermalizer unattended. The boil-out solution may foam and overflow
if rethermalizer is left unattended. Press the
switch to turn computer OFF to
control this condition.
1. Before turning the computer ON, close the drain valve and fill empty vessel with a mixture
of cold water to the overflow tube (use auto-fill by-pass switch as needed). Ensure water
solenoid by-pass switch is turned off when water filling is no longer desired. Add a
commercial grade detergent formulated to effectively clean and sanitize food-contact
surfaces. Follow instructions on container when mixing.
CAUTION
Use a commercial grade cleaner formulated to effectively clean and sanitize food-
contact surfaces. Read directions for use and precautionary statements of cleaner.
Particular attention should be paid to the concentration of cleaner and the length of
time the cleaner rests on the food-contact surfaces.
WARNING
If gas odors are detected, the appliance gas supply MUST be shut off at the main
shut-off valve, and the local gas company or authorized service agency contacted
for service.
2. Follow LIGHTING INSTRUCTIONS in Section 3.2. Press the switch to turn the
computer on. An illuminated dot between digits 1 and 2 in either LED display indicates
that the burners are lit. (AutoFill will add water if the boil-out solution level is inadequate.)
3. The Boil Mode is selected by pressing the
(L) button. The computer will display