ignition Failure
ignition Failure
Ignition failure: Indicates the fryer is not heating. It
is displayed when the oil temperature is above 450°F (232°C)
and the hi-limit has opened, halting the heating of the oil. It is
also displayed if the fryer looses its ability to heat oil.
2
3 4
DEF
GHI
JKL
MNO
PQR
STU
VWX
5
6
7 8
ABC
1
YZ-
09
+
*
12
2
1
Hi- limit Hi- limit
Hi-Limit: Displayed during a test of the hi-limit system.
2
3 4
DEF
GHI
JKL
MNO
PQR
STU
VWX
5
6
7 8
ABC
1
YZ-
09
+
*
12
2
1
Hi 2 bad
Hi 2 bad
Hi 2 Bad: Only displayed during a test of the hi-limit system.
Indicates the hi-limit has failed.