User Manual
FrSky Electronic Co., Ltd
Website:www.frsky-rc.com E-mail:frsky@frsky-rc.com Technical Support: sales4tech@gmail.com
Introduction
www.frsky-rc.com
FrSky 2.4GHz ACCST Taranis X9E Manual
FrSky Electronic Co., Ltd
Website:www.frsky-rc.com E-mail: frsky@frsky-rc.com Technical Support: sales4tech@gmail.com
www.frsky-rc.com
Cautions on handling antenna
Do not touch the antenna during operation. Doing so could interfere with transmission, causing a crash.
Do not carry the transmitter by the antenna. The antenna wire could break and prevent transmission.
Do not pull the antenna forcefully. The antenna wire could break and prevent transmission.
Specifications
Model Name: Taranis X9E
Number of Channels: 16 Channels (extensible to 32 channels)
Operating Voltage Range: 6~15V (2S, 3S Lipos are acceptable)
Operating Current: 260mA maximum (both RF module and backlit are on)
Operating Temperature: -10~60℃
Backlight LCD Screen: 212*64
Model Memories: 60 (extendable by SD card)
Compatibility: FrSky X series, D series and V8-II series receivers (plus other receivers if an external module
is used)
Taranis X9E-EU version is only compatible with X series receiver EU version.
●
●
●
●
●
Quad Ball Bearing Gimbals
Receiver Match
Audio Speech Outputs (values, alarms, settings, etc.)
Antenna Status Detection and Adjustment
Real-time Flight Data Logging
●
●
●
●
●
Receiver Signal Strength Indicator (RSSI) Alerts
Super Low Latency
Smart Port Supported
Vibration Alerts
Switch Numbers Extendable
Features
Battery Connector Polarity
FrSky Electronic Co., Ltd
Website:www.frsky-rc.com E-mail: frsky@frsky-rc.com Technical Support: sales4tech@gmail.com
www.frsky-rc.com
FrSky Electronic Co., Ltd
Website:www.frsky-rc.com E-mail: frsky@frsky-rc.com Technical Support: sales4tech@gmail.com
www.frsky-rc.com
Model Setup for Taranis X9E Internal RF Module
Model Setup for Taranis X9E External RF Module
Mode of Taranis X9E Compatible Receivers Number of Output Channels
D8
Mode of Taranis X9E-EU version Compatible Receivers Number of Output Channels
D16-EU X series-EU version Up to 16 channels
D16
LR12
X series (X8R, etc.)
L series (L9R, etc.)
Up to 16 channels
12 channels
8 channels
V8-II series in D mode (V8FR-II,
V8R7-II,V8R4-II,VD5M,etc.)
D series (D8R-II plus, D8R-XP,
D6FR,D4R-II,etc.)
Notice: Older V8 receivers are not supported by the internal module but can be used
with an external DJT module in V8 mode.
The EU version of Taranis X9E only has FrSky D16-EU Mode.
Overview
SA: 3 positions, Short Lever
SB: 3 positions, Long Lever
SC: 3 positions, Long Lever
SD: 3 positions, Short Lever
SE: 3 positions, Short Lever
SF: 2 positions, Long Lever
SG: 3 positions, Short Lever
SH: 2 positions, Momentary;
Long Lever
Notice: You can choose the Switch and define its positions in the Mixer menu.
The DIY switch port is a free replacement switch position .
The number of switches can be extended by the DIY switch port.
POWER
MENU
PAGE
E
X
I
T
T1
T2
S1
S2
T3
T4
1
2 3 4 5
6
7 8 9 10
1
2 3 4 5
6
7 8 9 10
Segment LCD Screen Antenna of X9E Internal Module
DIY switch port
SF
SA
SB SC
SD
SH
SG
SE
F1 F2
LS RS
Digital Trim
Power swich
Left rotation: +
Right rotation: -
Press: Enter
Stick
MENU
EXIT
PAGE
Control board Hook
Linear
LCD Display
(J3)
(J4)
Stick
(J2)
(J1)
Charge Jack
Power Indicater LED
TF card slot Earphone Port Trainer Port
USB Port
Antenna Port of X9E External Module
Thank you for purchasing the FrSky 2.4GHz ACCST TARANIS X9E digital telemetry radio system. In order to make
the best use of your system and to fly safely, please read this manual carefully. If you have any difficulties while using
your system, please consult the manual, your hobby dealer, or FrSky technical support.
Due to unforeseen changes in production, the information contained in this manual is subject to change without notice.
Meanings of Special Markings
Pay special attention to safety where indicated by the following marks:
DANGER - Procedures which may lead to dangerous conditions and cause death/serious injury if not
carried out properly.
WARNING - Procedures which may lead to a dangerous condition or cause death or serious injury to the
user if not carried out properly or procedures where the probability of superficial injury or physical damage is
high.
CAUTION - Procedures where the possibility of serious injury to the user is small, but there is a danger of
injury, or physical damage, if not carried out properly.
= Mandatory = Prohibited
Warning: Always keep electrical components away from small children.
The internal RF module of FrSky Taranis X9E is newly developed by FrSky under the name of XJT.
Enter the MODEL SETUP menu (for details, refer to the Guide included on the SD card, or download it from
FrSky website)
Notice:
● SBUS port always outputs, No Pulse could not
perform properly on it. Set “Hold” or “Custom” for
SBUS port.
● The above instructions do not apply to D-series
receivers, which require the internal RF module of
Taranis X9E to be in D8 mode. For these receivers,
failsafe must be set on the receiver side (see receiver
instructions).
Step 1: Set the Mode for Taranis X9E Internal RF
Refer to the table below and set the Taranis X9E to the mode corresponding to your receiver (D8, D16 or LR12 ).
Step 2: Set the Channel Range
The internal RF module of Taranis X9E supports up to 16 channels. The channel range is configurable, and
needs double check before use.
Step 3: Set the Receiver Number
When you create a new model, the system will assign you a receiver number automatically, but this can be
easily changed. The range of the receiver number is 00-63, with the default number being 01 (use o 00 is not
recommended). Once the receiver is set to the desired number and is bound to the Taranis X9E, the bind
procedure will not need to be repeated unless the receiver number is changed, In this case, either set the
receiver number to the previous one, repeat the bind procedure.
Step 4: Bind
Bind refers to Taranis X9E binding mode. Move the cursor to “Bind”, press ENTER button, the cursor will
flash and the speaker will beep to remind you that the RF module has entered the bind mode. Then put your
receiver into binding mode and finish the bind procedure(refer to the receiver’s manual for details).Press
Enter or EXIT to exit.
Step 5: Set Failsafe mode
There are 4 failsafe modes: No Pulse , Hold , Custom,Receiver(this mode only used above opentx-v2.0.0
firmware ).
● No Pulse: on loss of signal the receiver produces no pulses on any channel. To use this type, select it in the
menu and wait 9 seconds for the failsafe to take effect.
● Hold: the receiver continues to output the last positions before signal was lost. To use this type, select it in
the menu and wait 9 seconds for the failsafe to take effect.
● Custom: pre-set to required positions on lost signal. Move the cursor to “Set” and press ENTER, you will
see FAILSAFE SETTING screen below. Move the cursor to the channel you want to set failsafe on, and press
ENTER. When moving the corresponding sticks or switches, you will see the channel bar moving. Move the
channel bar to the place you want for failsafe and long press ENTER to finish the setting. Wait 9 seconds
before the failsafe takes effect.
● Receiver: set the failsafe on the receiver(see receiver instructions) in D16 mode, select it in the menu and
wait 9 seconds for the failsafe to take effec.
Step 6: Range
Range refers to Taranis X9E range check mode. A pre-flight range check should be done before each flying
session. Move the cursor to “Range” and press ENTER. In range check mode, the effective distance will be
decreased to 1/30. Press Enter or EXIT to exit.
The external RF module can be powered on or off by software. The setup process is the same as that for the
internal RF .If you use other brand RF module than FrSky, please choose PPM mode.
Ensure that the battery connector polarity is correct when connecting batteries other than the provided
8cell NiMH battery into the battery compartment, otherwise the Taranis X9E might not be powered on.
Please connect the provided battery in the battery compartment before use.
The eight-cell NiMH battery is for use only in your TARANIS X9E.
Be sure to use the built-in battery charger to charge the battery.
Be careful not to drop the battery.
Don't pull the battery wires as this could produce, short-circuits and cause the battery to explode.
Do not remove the battery from the TARANIS X9E transmitter while the voltage warning is blinking
as this could cause internal settings and memories to be destroyed.
Do not use the transmitter if a “Backup Error” warning occurs.
Be sure to turn off the Taranis X9E before charging the battery.
The Power Indicator LED will be on during charging, and be off after the charging is finished.