Technical Specifications

Product name:
FROTH
-
PAK
650BF HFC CLASS A POLYOL
Spray Polyurethane Foam
Issue Date:
Page 4 of 19
absolutely necessary. Treatment of exposure should be directed at the control of symptoms and the
clinical condition of the patient.
5. FIREFIGHTING MEASURES
Suitable extinguishing media: Water fog or fine spray. Dry chemical fire extinguishers. Carbon
dioxide fire extinguishers. Foam. Alcohol resistant foams (ATC type) are preferred. General purpose
synthetic foams (including AFFF) or protein foams may function, but will be less effective.
Unsuitable extinguishing media: Do not use direct water stream. May spread fire.
Special hazards arising from the substance or mixture
Hazardous combustion products: During a fire, smoke may contain the original material in addition
to combustion products of varying composition which may be toxic and/or irritating. Combustion
products may include and are not limited to: Carbon monoxide. Carbon dioxide. Hydrogen halides.
Unusual Fire and Explosion Hazards: Container may rupture from gas generation in a fire situation.
Blowing agent vaporizes quickly at room temperature. Violent steam generation or eruption may occur
upon application of direct water stream to hot liquids.
Advice for firefighters
Fire Fighting Procedures: Keep people away. Isolate fire and deny unnecessary entry. Use water
spray to cool fire exposed containers and fire affected zone until fire is out and danger of reignition has
passed. Fight fire from protected location or safe distance. Consider the use of unmanned hose
holders or monitor nozzles. Immediately withdraw all personnel from the area in case of rising sound
from venting safety device or discoloration of the container. Do not use direct water stream. May
spread fire. Move container from fire area if this is possible without hazard. Burning liquids may be
moved by flushing with water to protect personnel and minimize property damage. Contain fire water
run-off if possible. Fire water run-off, if not contained, may cause environmental damage. Review the
“Accidental Release Measures” and the “Ecological Information” sections of this (M)SDS.
Special protective equipment for firefighters: Wear positive-pressure self-contained breathing
apparatus (SCBA) and protective fire fighting clothing (includes fire fighting helmet, coat, trousers,
boots, and gloves). Avoid contact with this material during fire fighting operations. If contact is likely,
change to full chemical resistant fire fighting clothing with self-contained breathing apparatus. If this is
not available, wear full chemical resistant clothing with self-contained breathing apparatus and fight
fire from a remote location. For protective equipment in post-fire or non-fire clean-up situations, refer
to the relevant sections.
6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protective equipment and emergency procedures: Isolate area. Keep
unnecessary and unprotected personnel from entering the area. Keep personnel out of confined or
poorly ventilated areas. Keep upwind of spill. Spilled material may cause a slipping hazard. Ventilate
area of leak or spill. Confined space entry procedures must be followed before entering the area.
Refer to section 7, Handling, for additional precautionary measures. Use appropriate safety
equipment. For additional information, refer to Section 8, Exposure Controls and Personal Protection.
Environmental precautions: Prevent from entering into soil, ditches, sewers, waterways and/or
groundwater. See Section 12, Ecological Information.